This README.txt file was generated on <20210530> by ------------------- GENERAL INFORMATION ------------------- 1. Title of Dataset: Accuracy in the digital workflow for complete-arch implant rehabilitation 2. Author Information First Author Contact Information Name: Pan Yu Faculty: Faculty of Dentistry Email: yupan@hku.hk Corresponding Author Contact Information Name: Pow Edmond Ho Nang Faculty: Faculty of Dentistry Email: ehnpow@hku.hk Author Contact Information (if applicable) Name: Tsoi James Kit Hon Faculty: Faculty of Dentistry Email: jkhtsoi@hku.hk Author Contact Information (if applicable) Name: Lam Walter Yu Hang Faculty: Faculty of Dentistry Email: retlaw@hku.hk --------------------- DATA & FILE OVERVIEW --------------------- Directory of Files: A. Filename: precision study Short description: This is for the original study: Reproducibility of complete-arch implant scanning: effect of scan bodies. There are raw 3D models of optical scanning, processed models, measurements using Geomagic software and CMM. Numbers and SPSS tables recorded all raw data. And some tables and figures after analyzation. B. Filename: calibration study Short description: This is for the original study: A novel auxiliary device to improve the accuracy of intraoral implant scanning in complete edentulous arch. There are CAD drawings, raw 3D models of optical scanning, processed models, measurements using Geomagic software and CMM. Numbers and SPSS tables recorded all raw data. And some tables and figures after analyzation. C. Filename: alignment study Short description: This is for the original study: Effect of scan body geometry on accuracy of the computer-aided design in digital implant workflow. There are raw 3D models of optical scanning, processed models, measurements using Geomagic software and CMM. Numbers and SPSS tables recorded all raw data. And endnote files containing related literatures, some tables and figures after analyzation. D Filename: auxiliary study Short description: This is for the original study: A novel auxiliary device to improve the accuracy of intraoral implant scanning in complete edentulous arch. There are raw 3D models of optical scanning, processed models, measurements using Geomagic software. Numbers and SPSS tables recorded all raw data. And some tables and figures after analyzation. E: Filename: CAD Short description: This is for the original study: Error propagation of the digital workflow for complete-arch implant-supported frameworks. There are raw 3D models of optical scanning, processed models, measurements using Geomagic software and CMM. Numbers and SPSS tables recorded all raw data. And some tables and figures after analyzation. Additional Notes on File Relationships, Context, or Content (for example, if a user wants to reuse and/or cite your data, what information would you want them to know?): N.A. ----------------------------------------- DATA DESCRIPTION FOR: precision study ----------------------------------------- 1. Number of variables:4 2. Number of cases/rows: 30 3. Missing data codes: N.A. 4. Variable List A. Name: linear trueness Description: the absolute difference between the test linear values and the reference value (test-ref). B. Name: angular trueness Description: the absolute difference between the test angular values and the reference value (test-ref). C. Name: linear precision Description: the absolute difference among the test linear values (test-test). D. Name: angular trueness Description: the absolute difference among the test angular values (test-test). -------------------------- METHODOLOGICAL INFORMATION -------------------------- 1. Software-specific information: Name: Geomagic Control Version:2014 System Requirements: Windows XP Open Source? (Y/N): N Additional Notes(such as, will this software not run on certain operating systems?): NA 2. Equipment-specific information: Manufacturer: ZEISS Contura G2 RDS CMM, Germany Embedded Software / Firmware Name: Calypso 5.6.0000, ServicePack 6, Version 5.6.24, Carl Zeiss ----------------------------------------- DATA DESCRIPTION FOR: calibration study ----------------------------------------- 1. Number of variables:8 2. Number of cases/rows: 15*4*2=120 3. Missing data codes: N.A. 4. Variable List A. Name: linear vertical trueness Description: the absolute difference between the test linear values in the vertical plane and the reference value (test-ref). B. Name: angular vertical trueness Description: the absolute difference between the test angular values in the vertical plane and the reference value (test-ref). C. Name: linear horizontal trueness Description: the absolute difference between the test linear values in the horizontal plane and the reference value (test-ref). D. Name: angular horizontal trueness Description: the absolute difference between the test angular values in the horizontal plane and the reference value (test-ref). E. Name: linear vertical precision Description: the absolute difference among the test linear values in the vertical plane (test-test) F. Name: angular vertical precision Description: the absolute difference among the test angular values in the vertical plane (test-test) G. Name: linear horizontal precision Description: the absolute difference among the test linear values in the horizontal plane (test-test). H. Name: angular horizontal trueness Description: the absolute difference among the test angular values in the horizontal plane (test-test). -------------------------- METHODOLOGICAL INFORMATION -------------------------- 1. Software-specific information: Name: Geomagic Control Version:2014 System Requirements: Windows XP Open Source? (Y/N): N Additional Notes(such as, will this software not run on certain operating systems?): NA 2. Equipment-specific information: Manufacturer: IScan D104i, iMetric, Courgenay, Switzerland, Manufacturer:Zfx Evolution plus, Zimmer Biomet, USA, Manufacturer:3Shape D2000, 3Shape, Denmark, Manufacturer:KaVo Arctica Autoscan, KaVo Dental Excellent, Germany. Manufacturer: ZEISS Contura G2 RDS CMM, Germany Embedded Software / Firmware Name: Calypso 5.6.0000, ServicePack 6, Version 5.6.24, Carl Zeiss ----------------------------------------- DATA DESCRIPTION FOR: alignment study ----------------------------------------- 1. Number of variables:3 2. Number of cases/rows: 30*2=60 3. Missing data codes: N.A. 4. Variable List A. Name: 3D distortion of centroids Description: the absolute distance of scan body/implant centroids between the original scan and aligned model. B. Name: surface distortions Description: the surface distortions (Root-mean-square) between the original scan and CAD model in the implant library. C. Name: distortion of inter-MUA distance Description: the inter-MUA distance difference between the original scans and the aligned model. -------------------------- METHODOLOGICAL INFORMATION -------------------------- 1. Software-specific information: Name: Geomagic Control Version:2014 System Requirements: Windows XP Open Source? (Y/N): N Additional Notes(such as, will this software not run on certain operating systems?): NA Name: EXOCAD, Woburn, MA, USA Version:N.A. System Requirements: Windows XP Open Source? (Y/N): N Additional Notes(such as, will this software not run on certain operating systems?): NA 2. Equipment-specific information: Manufacturer: Zfx Evolution plus, Zimmer Biomet, USA, ----------------------------------------- DATA DESCRIPTION FOR: auxiliary study ----------------------------------------- 1. Number of variables:4 2. Number of cases/rows: 10*4=40 3. Missing data codes: N.A. 4. Variable List A. Name: linear trueness Description: the absolute difference between the test linear values and the reference value (test-ref). B. Name: angular trueness Description: the absolute difference between the test angular values and the reference value (test-ref). C. Name: linear precision Description: the absolute difference among the test linear values (test-test). D. Name: angular trueness Description: the absolute difference among the test angular values (test-test). -------------------------- METHODOLOGICAL INFORMATION -------------------------- 1. Software-specific information: Name: Geomagic Control Version:2014 System Requirements: Windows XP Open Source? (Y/N): N Additional Notes(such as, will this software not run on certain operating systems?): NA Name: EXOCAD, Woburn, MA, USA Version:N.A. System Requirements: Windows XP Open Source? (Y/N): N Additional Notes(such as, will this software not run on certain operating systems?): NA 2. Equipment-specific information: Manufacturer: Trios 3, 3ShapeA/S, Copenhagen, Denmark Manufacturer: IScan D104i, iMetric, Courgenay, Switzerland ----------------------------------------- DATA DESCRIPTION FOR: CAM ----------------------------------------- 1. Number of variables:4 2. Number of cases/rows: 10*2*2+5*2=50 3. Missing data codes: N.A. 4. Variable List A. Name: linear trueness Description: the absolute difference between the test linear values and the reference value (test-ref). B. Name: angular trueness Description: the absolute difference between the test angular values and the reference value (test-ref). C. Name: linear precision Description: the absolute difference among the test linear values (test-test). D. Name: angular trueness Description: the absolute difference among the test angular values (test-test). -------------------------- METHODOLOGICAL INFORMATION -------------------------- 1. Software-specific information: Name: Geomagic Control Version:2014 System Requirements: Windows XP Open Source? (Y/N): N Additional Notes(such as, will this software not run on certain operating systems?): NA Name: EXOCAD, Woburn, MA, USA Version:N.A. System Requirements: Windows XP Open Source? (Y/N): N Additional Notes(such as, will this software not run on certain operating systems?): NA Name: HyperMILL, OPEN MIND Technologies AG, Germany Version:N.A. System Requirements: Windows XP Open Source? (Y/N): N Additional Notes(such as, will this software not run on certain operating systems?): NA 2. Equipment-specific information: Manufacturer: Trios 3, 3ShapeA/S, Copenhagen, Denmark Manufacturer: IScan D104i, iMetric, Courgenay, Switzerland Manufacturer:308 B, Willemin-Macodel SA, Suisse Manufacturer: ZEISS Contura G2 RDS CMM, Germany Embedded Software / Firmware Name: Calypso 5.6.0000, ServicePack 6, Version 5.6.24, Carl Zeiss